Chapter 3: FRU Removal and Replacement Procedures
Opening and Closing the Node
84 Quantum DXi6900 G1 User’s Guide
Figure 42 Replacing the Node
Cover
4 Place the cover onto the Node chassis and offset the cover slightly
back so that it clears the chassis hooks and lays flush on the chassis.
5 Push down the latch to move the cover into the closed position.
6 Rotate the latch release lock in a clockwise direction to secure the
cover.
7 Pull the inner slide rails out of the rack until they lock into place (see
Figure 43).
Node cover
Latch Latch release lock