RADWIN2000UserManual Release2.8.30 915
RADWINManagerCommunityStrings
notpossibletomanagetheODUifthereadwriteorthereadCommunityvaluesare
forgotten.AnewCommunityvaluemaybeobtainedfromRADWINCustomerSupportforthe
purposeofsettingnewCommunity.Youmustalsohaveavailabletheserialnumberorthe
MACaddressoftheODU.
ThereadwriteCommunitystringsandreadonlyCommunitystringshaveaminimumoffive
alphanumericcharacters.(bru1andbru4097arenotpermitted).Changingthetrap
Communityisoptionalandisdonebyclickingthecheckbox.
EditingSNMPv1CommunityStrings
TheCommunitychangedialogboxisavailablefromtheConfiguration|Securitytab.Both
readwriteandreadonlycommunitiesmustbedefined.
Onlog gingonforthefirsttime,usethefollowingasthecurrentCommunity:
ForReadWriteCommunity,usenetman.
ForReadOnlyCommunity,usepublic.
ForTrapCommunity,usepublic
TochangeaCommunitystring:
1.TypethecurrentreadwriteCommunity(defaultisnetman).
2.Choosethecommunitiestobechangedbyclickingthecheckbox.
3.TypethenewCommunitystringandretypetoconfirm.Acommunitystringmust
containatleastfiveandnomorethan32charactersexcludingSPACE,TAB,andany
of“>#@|*?;."
4.ClickOKtosave.
EditingSNMPv3Passwords
Tocommencetheprocess,youmusten terthecurrentReadWriteCommunitypasswordas
showninthefirstfieldofFigure99below.ChangetheReadWriteandReadOnlypasswords
asindicated.Apasswordmustbebetween8and31characterslong.Thesamecharacter
restrictionsforthe SNMPv1communitystringsalsoapplyhere.