RADWIN2000UserManual Release2.8.30 10‐25
ReplacinganODU
ReplacinganODU
Priortoany actionensurethatbothODUshavethesamesoftwareversion.Youcanseethis
ontheinventorypanelsforeachsite.
ForSiteA,clickSiteA|InventoryandnotetheODUsoftwarever sion.RepeatthisforSiteB
usingSiteB|Inventory.
IfeitherODUhasanoldsoftwareversion,performasoftwareupgrade.Itisimportantto
configurethenewODUidenticallytotheoldODUtoavoidconfigurationmismatches,which
willdisruptthelink.
AnODUmaybereconfiguredinseveralways.
•Usethebackupconfiguration
Ifabackupoftheconfigurationisavailable,restorethatconfigurationusingSiteA|
Restore.RecallthatbackupfilesarelinkedtoaMACaddress.Thiswon’tworkforan
identicalreplacementODU.
• Manualconfiguration
ThenewODUcanbeconfiguredmanuallyaccordingtothelinkconfiguration.
RemembertousethesamesettingsforLinkID,channels,linkpassword,IPaddresses,
andnames.
RestoringFactorySetup
Torestorefactorysetup:
•UseSiteConfigurationAorB,andthenOperations|RestoreDefaults.Alwaysrestore
theover‐the‐airsite(B)first.
OnlineHelp
OnlinehelpcanbeaccessedfromtheHelpmenuonthemainwindowoftheRADWIN
Manager.
Nosignal
CompletetheinstallationprocedurefromtheRADWINManager
Checktheantennaalignment.Checkthattheradioconfigurationofbothsite
AandsiteBunitsisthesame(channelsettingsandLinkID)
Weaksignal
received
Checktheantennaalignment,reconfigurethelink
CheckthealignmenttonesoundstheBestSignalsequence
Table10‐8:SystemTroubleshooting(Continued)
Symptom Remedy