AppendixE:
ExternalAlarmsSpecification
ExternalAlarmsSpecification
TheIDUCandIDUEsupportexternalinputandoutputalarmsthroughastandardDB25pin
femaleconnector(seepageB3forpinoutdetails).
Inputalarms
Theinputalarmsareraisedbyeventsfromexternalequipment,suchasa
firewarning,dooropenorairconditionerfailure.Theyareuserdefined.
Outputalarms
Outputalarmsaregeneratedthroughdrycontactrelaystoindicate
varioussystemeventssuchassynclossordisconnection.Analarmis
raisedifatleastoneoftheconditionsinoneofthetablesbelow,ismet.
IDUCandIDUEAlarms
TableE1:IDU-C/E - Output Alarms Description
Alarm Description AlarmOnConditions AlarmOffCondition
Output1
Airinterface
Alarm
•Linkisdown
•Linkininstallation
mode
•Linkauthentication
problem
Linkisuporequipmentalarm
isON
Output2
Equipment
Alarm
•BuiltinTest(BIT)error
•Noconnectiontothe
ODU
BothODUandIDUarein
operationalstate