RADWIN2000UserManual Release2.8.30 4‐12
Cablesandconnectors
Cablesandconnectors
• ODUgroundingcable10AWG
• ODU‐PoEcable(outdoorclass,CAT‐5e,4twistedpairs,24AWG):
• Upto100m.for100BaseTconnection.
• Fora1000BaseTconnection(HBSonly)useanODU‐PoEcablenolongerthan75m.
• ExternalCAT‐5ecablediametershouldbebetween7‐9mmtoensurewaterproof
sealing.
SafetyPractices
PreventingOverexposuretoRFEnergy
ToprotectagainstoverexposuretoRFenergy,installtheODUssoastoprovideandmaintain
minimalseparationdistancesfromallpersons.
Whenthesystemisoperational,avoidstandingdirectlyinfrontoftheantenna.StrongRF
fieldsarepresentwhenthetransmitterison.TheODUmustnotbedeployedinalocation
whereitispossibleforpeopletostandorwalkinadvertentlyinfrontoftheantenna.
Grounding
AllRADWINproductsshouldbegroundedduringoperation.Inaddition:
• AllODUsshouldbeearthedbyawirewithdiameterofatleast10AWG.
RADWIN2000ODUsmustbeproperlygroundedtoprotectagainstlightning.Itisthe
user'sresponsibilitytoinstalltheequipmentinaccordancewithSection810ofthe
NationalElectricCode,ANSI/NFPANo.70‐1984orSection54oftheCanadianElectrical
Code.Thesecodesdescri becorrectinstallationproceduresforgroundingtheoutdoor
unit,mast,lead‐inwireanddischargeunit.Italsolaysdownthesizeofgrounding
conductorsandconnectionrequirementsforgroundingelectrodes.RADWIN2000
ODUsmustbegroundedtoaProtectiveEarthinaccordancewiththeLocalElectrical
Regulations.
• TheearthlugonanyIDUshouldbeconnectedtotheprotectiveearthatalltimes,bya
wirewithadiameterof18AWGorwider.Rack‐mountedequipmentshouldbe
mountedonlyinearthedracksandcabinets.
Further,youshould ‐
• Alwaysmakethegroundconnectionfirstanddisconnectitlast
• Neverconnecttelecommunicationcablestoungroundedequipment
Note
For1000BaseT,youshoulduseRADWINsuppliedODU‐PoEcables,which
guarantees1Gbperformance.RADWINcannotguarantee1Gb
performanceifyouusethirdpartycables.