RADWIN2000UserManual Release2.8.30 432
MountingtheLightningProtectionDevices
7.Connectthe0.5mCAT5ecabletotheBottomoftheLPU.
8.Connecttheotherend(viatheindooraccesspoint)totheIDU.
9.InsulatebothLPUconnections.Seethenextsection,AdditionalConsiderationfor
Waterproofing below.
AdditionalConsiderationforWaterproofing
LightningProtectorsandEthernetRepeaters
Iftheseunitsareinstalledatlocationsheavi lyexposedtoheavydust,rainorcorrosive
moisture (forexample,closetothesea),youshouldprotectthemfurtherasinthefollowing
procedure.Intheremainderofthissection,“unit”referstoeitheraLightningProtectionUnit
oraRepeater.
Tosealaunitag ainstexcessivedustandmoisture:
1.ObtainahighqualitysealingmaterialsuchasScotch23Tape¾”wide,from3Mto
ensureIP67compliantprotectionagainstwateranddust.
2.Cuttwopieceseach25cmlong,ofScotch23splicingtape.Removetheplasticcover
toexposethetackysideofthesealingtapeasshowninFigure447.
Figure447:Exposingthetacksideofthesealingtape
3.AfterconnectingtheshortCAT5IDU/ODUcable(providedinthebox)fromtheODU
totheunit,tightenthecableglandcapfirmlyandusetheinsulationtapescotch23
tofullycoverbothofthecableglands.
4.ConnectthetapewithtackysideuponthecableglandcapandtheCAT5cable.Start
atStartPointatthebottomofthecableglandasshowninFigure448.FinishatEnd
Pointofthe CAT5cable,2.5cmaftertheendoftheshrinktubing.Stretchthetape
andapplyhalfoverlappedtoformgapfreejoint.