RADWIN2000UserManual Release2.8.30 4‐31
MountingtheLightningProtectionDevices
ToinstallaLPUonapoleadjacenttoanODU(HBSorHSU):
1.MountoneLPUonthe
ODUpole,ascloseas
possibletotheODU.
2.GroundtheLPUtothe
poleusingthegrounding
lug.
3.Connectthe0.5meter
CAT‐5ecabletotheIDU
portoftheODU.
4.Connecttheotherendof
thecabletothetopof
theLPU.
5.TightenthetopcableLPU
glandcap.
6.ConnectthemainODU‐
IDUcablefromtheIDUtothebottomendoftheLPU.
7.TightenthebottomcableLPUglandcap.
8.RunthemainODU‐IDUcabletowardstheIDUlocation.
9.InsulatebothLPUconnections.Seethenextsection,AdditionalConsiderationfor
Waterproofing below.
ToinstallaLPUonawalladjacenttoanIDU(PoEorIDU‐H):
1.Usethesuppliedwall
clamptomountthe
secondLPUasclose
aspossibletothe
indooraccesspoint
totheIDU.
2.GroundtheLPUto
anearthstripusing
thegroundinglug.
3.Removethetop
cableLPUglandcap
togetherwiththe
rubbersealingtube.
4.ThreadtheIDUcable
fromtheupperLPU,throughtheremovedcapfromthepreviousstep.
5.PlugitintothetopoftheLPU.
6.ScrewdownandtightentheLPUcap.