RADWIN2000UserManual Release2.8.30 12‐7
LinkConfigurationandHSS
• ExternalPulses:
ToconfiguretheOperationalStatesoftheHubSiteunit
1.ClicktheEnabledcheckbox
2.ClicktheConfigurebutton
TheHubSiteConfigurationdialogboxwiththecurrentstatusoftheODUsisdis‐
played.
3.Selectthetypeofunitconfigurationfromthedrop‐downlist.
4.SelecttheappropriateRFPradiobutton.SomeRFPoptionsmaybedisabled
dependingonthebandwidthpreviouslyselected.
Table12‐1:ExternalPulseStatus
HSSSyncStatus Meaning
Color
code
Generating ODUisHSMandgeneratesthesyncpulse
GreenDetected ODUisHSCanddetectsthesyncpulse
Notdetected ODUisindependent
Generatinganddetected HSM,butotherHSMpresent
Orange
Generatingand
ImproperlyDetected
RADWIN2000ODUisHSM,butdetectsaHSMsignalthat
isnotRFPE
Notdetected HSCbutnoHSMpresent
Improperlydetected
HSCbutHSMpulsedoesn’tfittheHSCasconfigured.ODU
stopstransmitting.
Red
Note
Takecaretoavoidincorrectconfigurationofbandwidth,RFPortoset
multipleHubSyncMasters,assysteminterferencecanoccur.RADWIN
Managerprovideserrormessagesandtooltipsifthesystemisconfigured
withmismatches.