RADWIN2000UserManual Release2.8.30 435
MountingtheEthernetRepeater
MountingtheEthernetRepeater
TheRADWINEthernetrepeaterenablesyoutoextendthePoEtoODUcablebeyondthe
100mlimit(butnomorethan200m).Theunitlooksphysicallylikethelightningprotection
deviceinFigure417.Itsuseisverysimpleasshowninthefollowingschematic:
Figure451:singanEthernetrepeaterwithlightningprotectors
ConnectinganODUtoanIDU
TheODUIDUcableconductsalltheusertrafficbetweentheIDUandtheODU,andalso
providespowertotheODU.ThemaximumlengthoftheODUIDUcableis100m(328ft)in
accordancewith10/100BaseTstandards.
TheODUIDUcableissuppliedpreassembledwithRJ45connectors,atthelengthspecified
whenordering,orasacabledrumwithspareconnectors.IftheODUIDUcablewasnot
ordered,useanoutdoorclass,CAT5e24AWGshieldedcable.See
AppendixBforWiring
Specifications.
ToconnecttheODUtotheIDU,routethecablefromtheODUtotheIDU,securethecable
alongitspathandconnectthecabletotheODURJ45connectorontheIDU(seeitemBin
Figure438above).
Note
TheEthernetrepeatercannotbeusedwithGbEIDUODUcables.