EasyManua.ls Logo

Radwin 2000 - Figure 15-4 Servicesc

Radwin 2000
509 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RADWIN2000UserManual Release2.8.30 155
InstallingaRADWINMHS
5.EstablishSecondaryLinkintheusualway,withHSSenabled.Thetwolink
frequenciesshouldbeatleast5MHzapart.
6.ConnecttheMHScablesatSitesAandBasshowninFigure151andFigure153
above.
7.RuntheConfigurationWizardforPrimaryLink.ActivateTDMservicesintheusual
way.NavigatetotheHotStandbytab,intheServicesConfigurationpanel:
Figure154:ServicesConfigurationPanel:HotStandbymodeselection
CheckthePrimarybuttontoconfigurePrimaryLinkastheprimarylink.
8.CompletetheWizard,andthenmovetoSecondaryLink.
9.Repeatstep7forSecondaryLink.FortheServicesHotStandbytab,thistime,check
theSecondarybutton.
10.CompletetheWizard.
11.AtSite1.2,reconnecttheHotStandbyPatchpaneltotheexternalequipment.
Fromthispointon,wewillsimplyrefertoprimaryandsecondarylink(nocapitalizednames).
Attheendoftheprocess,theRADWINManagermainwindowsshouldlooklikethis:

Table of Contents

Related product manuals