RADWIN2000UserManual Release2.8.30 D50
RADWINManagerTraps
RADWINManagerTraps
TheRADWINManagerapplicationissuestrapstoindicatevariousevents.Thesetrapsare
shownintheRADWINManagerrEventsLog.
AlistofTrapMessagesasdisplayedbytheRADWINManagerisshowninTable105.
poePortClear 244 normal IndicatesthePOEportstatus
changedtoconnected.
Containstwoparameters:
1‐Description:POEportstatus
changedtoconnected‐%s
2‐%sIstheEth.mode(speed&
duplex)
poePowerConsumptionClear 245 normal IndicatesthePOEpower
consumptionisvalid.
Containstwoparameters:
1‐Description:POEconsumption
withinlimits.portisopened.
2‐%sIstheEth.mode(speed&
duplex)
incompatibleHbsHsu 246 normal IncompatibleHBS/HSUsoftware
versions‐noservice.
mobilityLinkOff 247 normal Mobility‐Linkcannotbeestablished
dueto:
1‐TheHBSdoesnotsupport
Mobility
2‐LackofresourcesintheHBSfor
HSUlevel
enterLocalConnection 248 normal EnteringLocalConnection
(Broadcas t)Mode.
hobupActiveStateFaultyClear 249 normal Thisclearalarmwillindicatethatthe
HotBackupunitisinactivestate.
Containsasingleparameter,whichis
itsdescription:
1‐Description:HotBackup%sunit
activated.
%s‐PrimaryOrSecondaryUnit
hobupStandbyState 250 normal Containsasingleparameter,whichis
itsdescription:
1‐Description:HotBackupin
Standbystate:%sunit.
%s‐PrimaryOrSecondaryUnit
TableD3:MIBTraps(Sheet14of14)