RADWIN2000UserManual Release2.8.30 2‐2
Newfeatures:
Newfeatures:
• SupportfortwoTDMinterfacesforA‐Series10Mproducts
• SupportforaRadarSignalMitigationmechanismtodealwithfalseradarsignaldetec‐
tion
EthernetHubSiteSynchronization(HSSoE)
HSSoEmaybeusedtocollocateseveralRADWIN2000radioswithoutuseofHSScablesand
anexternalHSSunit.Theconditionsforitsuseare:
• TheODUhardwarelevelsmustbeasinthefollowingtable:
• EthernetconnectivityisrequiredbetweencollocatedunitsusinganyoneofanIDU‐C,
IDU‐EorIDU‐H.
SomeHSSoEhighlightsare:
• HSSoEsupportsbothEthernetandTDMservices
• HSSoEconfigurationusingtheRADWINManagerissimilartothatoftheexistingSerial
HSS(SHSS)
• HSSoEusesVLANtoseparateHSSoEsyncsignalsfromtraffic
• HSSoEenabledODUswithaSyncportmaybecollocatedwithSerialHSSenabledunits
ExtremeColdResistantProducts
VariantsofexistingODUandIDU‐Cproductscapableofoperatingattemperaturesaslowas‐
55ºCareavailable.PleasecontactCustomerSupportfordetails.
SNMPv3Support
• Confidentiality‐Encryptionofpacketstopreventunauthorized“snooping”
•Integrity‐Ensurethatpacketshavenotbeentamperedwithintransitincludingan
optionalpacketreplayprotectionmechanism
• Authentication‐Validationofmessagesource
•Security‐DESsecuritylevel
• AppliestoRADWIN2000A,RADWIN2000BandRADWIN2000C.series
Table2‐1:HSSoESupport‐MinimumHardwarelevels
Family
Hardware
Level
RADWIN2000A 4
RADWIN2000B
RADWIN2000C
RADWIN2000X
9