RADWIN2000UserManual Release2.8.30 A‐6
ODU
ThefollowingMaxTxPowerlimitationsapplytoallproductssupportingthe3.5GHzETSI
band:
Management
Environmental
6.4
ETSI
5.928‐6.400
5/1 0 /
20
No Lowtemperature,to‐35°C
Universal
5.895‐6.4050 10
No N/A
5.890‐6.410 20
5.725‐6.400
5/1 0 /
20/40
No N/ALowtemperature,to‐55°C
OccupiedSub‐
Band
GHz
Center
Frequency
GHz
Mode
Channel
Bandwidth
MHz
MaxTx
Power
dBm
Frequency
Step
KHz
3.403‐3.490 3.413‐3.480
Inactive 5,10,20
17
2503.470‐3.610 3.480‐3.600 23(†)
3.590‐3.710 3.600‐3.700 25(‡)
Note
(†)The3.480GHzfrequencyisoverlapped,occurringintwodifferentbands
asshown.Ifyouwishtousethe3.480GHzfrequency,youshouldsetMax
TXPowerto17dBm.
(‡)The3.600GHzfrequencyisoverlapped,occurringintwodifferentbands
asshown.Ifyouwishtousethe3.600GHzfrequency,youshouldsetMax
TXPowerto23dBm.
ManagementApplication(per
link)
RADWINManager
WebbasedmanagerforRADWIN2000BandRADWIN
2000Cseries.
Protocol
SNMPandTelnet
NMS
RADWINNMS
OperatingTemperatures
ODU:‐35°Cto+60°C/‐31°Fto+140°F
Humidity
100%condensing,IP67(totallyprotectedagainstdust
andagainstimmersionupto1m)
Storage
‐40°to85°C/‐40°Fto185°F
Band
(GHz)
Regulation
Occupied
FrequencyRange
(GHz)
CBW
(MHz)
DFS? Compliance(Notes)