RADWIN2000UserManual Release2.8.30 D‐10
MIBParameters
winlink1000OduAirSSID 1.3.6.1.4.1.4458.1000.1.5.3 DisplayString RW ReservedfortheManagerapplicationprovided
withtheproduct.TheSectorIDinPoint‐To‐
Multi‐Pointsystems.
winlink1000OduAirTxPower 1.3.6.1.4.1.4458.1000.1.5.4 Integer RW RequiredTransmitpowerindBm.Thisisa
nominalvaluewhiletheactualtransmitpower
includesadditionalattenuation.Theminand
maxvaluesareproductspecific.Achangeis
effectiveimmediately.
winlink1000OduAirSesState 1.3.6.1.4.1.4458.1000.1.5.5 Integer RO CurrentLinkState.Thevalueisactive(3)during
normaloperation.
winlink1000OduAirMstrS lv 1.3.6.1.4.1.4458.1000.1.5.6 Inte ger RO Thisparameterindicatesifthedevicewas
automaticallyselectedintotheradiolinkmaster
orslave.Thevalueisundefinedifthereisno
link.Thevalueisrelevantonlyforpointto
pointsystems.
winlink1000OduAirResync 1.3.6.1.4.1.4458.1000.1.5.8 Integer RW Settingthisparameterto1willcausethelinkto
restartthesynchronizationproces s.
winlink1000OduAirRxPower 1.3.6.1.4.1.4458.1000.1.5.9.
1
Integer RO ReceivedSignalStrengthindBm.Relevantonly
forpointtopointsystems.
winlink1000OduAirTotalFrames 1.3.6.1.4.1.4458.1000.1.5.9.
2
Counter RO Totalnumberofradioframes.
winlink1000OduAirBadFrames 1.3.6.1.4.1.4458.1000.1.5.9.
3
Counter RO TotalnumberofreceivedradioframeswithCRC
error.Thevalueisrelevantonlyforpointto
pointsystems.
winlink1000OduAirCurrentRate 1.3.6.1.4.1.4458.1000.1.5.9.
4
Integer RO Deprecatedparameter.Actualrateoftheair
interfaceinMbps.ForChannelBandwidthof
20105MHzdividethevalueby124
respectively .
winlink1000OduAirCurrentRateIdx 1.3.6.1.4.1.4458.1000.1.5.9.
5
Integer RO Indexofcurrentairrate.
winlink1000OduAirTxPower36 1.3.6.1.4.1.4458.1000.1.5.1
0
Integer RW Deprecatedparameter.Actualbehaviorisread‐
only.
winlink1000OduAirTxPower48 1.3.6.1.4.1.4458.1000.1.5.1
1
Integer RW Deprecatedparameter.Actualbehaviorisread‐
only.
winlink1000OduAirCurrentTxPower 1.3.6.1.4.1.4458.1000.1.5.1
2
Integer RO CurrentTransmitPowerindBm.Thisisa
nominalvaluewhiletheactualtransmitpower
includesadditionalattenuation.
winlink1000OduAirMinFrequency 1.3.6.1.4.1.4458.1000.1.5.1
3
Integer RO MinimumcenterfrequencyinMHz.
winlink1000OduAirMaxFrequency 1.3.6.1.4.1.4458.1000.1.5.1
4
Integer RO MaximumcenterfrequencyinMHz.
winlink1000OduAirFreqResolution 1.3.6.1.4.1.4458.1000.1.5.1
5
Integer RO CenterFrequencyresolution.Measuredin
MHzifvalue<100otherwiseinKHz.
winlink1000OduAirCurrentFreq 1.3.6.1.4.1.4458.1000.1.5.1
6
Integer RO CurrentCenterFrequency.MeasuredinMHzif
centerfrequencyresolutionvalue<100
otherwiseinKHz.
winlink1000OduAirNumberOfChan
nels
1.3.6.1.4.1.4458.1000.1.5.1
7
Integer RO Numbe rofchannelsthatcanbeused.
winlink1000OduAirChannelsTable N/A Tableofchannelsus edbyautomaticchannels
selection(ACS).
winlink1000OduAirChannelsEntry N/A ACSchannelstableentry.INDEX{
winlink1000OduAirChannelsIndex}
winlink1000OduAirChannelsIndex 1.3.6.1.4.1.4458.1000.1.5.1
8.1.1
Integer RO ChannelIndex.
winlink1000OduAirChannelsFreque
ncy
1.3.6.1.4.1.4458.1000.1.5.1
8.1.2
Integer RO ChannelfrequencyinMHz.
TableD‐2:PrivateMIBParameters(Sheet5of31)
Name OID Type
Access
Description