MIBParameters
winlink1000IduEthernetGbeSuppor
ted
1.3.6.1.4.1.4458.1000.2.3.6 Integer RO SupportedGigabitEthernetinIDU.
winlink1000IduEthernetOduInError
s
1.3.6.1.4.1.4458.1000.2.3.7 Counter RO Thenumberofinboundpack etsthatcontained
errorspreventingthemfrombeingdeliverable
toahigherlayerprotocol.
winlink1000IduBridgeTpAging 1.3.6.1.4.1.4458.1000.2.4.4.
2
Integer RW Timeoutinsecondsforaging.Notethatforthis
parametertobeeffectivetheODUmustbe
configuredtoHUBmode.Achangeiseffective
immediately.
winlink1000IduTdmTxClockAvailStat
es
1.3.6.1.4.1.4458.1000.2.6.1.
1
Integer RO AvailablestatesoftheTDMTransmitClock
Controleachinputstatusisrepresentedbya
bit.Whenthestateisavailablethebitvalueis
1.Whenthestateisunavailablethebitvalue
is0.Theavailablestatesare:bit2=
Transparentbit3=LocalLoopTimedbit
4=
RemoteLoopTimedbit5=LocalInternalbit6
=RemoteInternal
winlink1000IduTdmT xClockDesiredS
tate
1.3.6.1.4.1.4458.1000.2.6.1.
2
Integer RW RequiredstateoftheTDMTransmitClock
Control.Achangeiseffectiveafterreactivation
oftheTDMservice.
winlink1000IduTdmTxClockActualSt
ate
1.3.6.1.4.1.4458.1000.2.6.1.
3
Integer RO ActualstateoftheTDMTransmitClockControl.
winlink1000IduTdmMasterClockAva
ilOptions
1.3.6.1.4.1.4458.1000.2.6.2.
1
Integer RO AvailableoptionsoftheTDMMasterClock
Controleachinputstatusisrepresentedbya
bit.Whentheoptionisavailablethebitvalue
is1.Whentheoptionisunavailablethebit
valueis0.Theavailableoptionsare:bit2=
Automaticbit3=Tr unk#1bit4
=Trunk#2bit
5=Trunk#3bit6=Trunk#4Whennooptions
areavailablethereturnedvalueis:1
winlink1000IduTdmMasterClockDes
ired
1.3.6.1.4.1.4458.1000.2.6.2.
2
Integer RW RequiredTDMMasterClock.Achangeis
effectiveafterreactivationoftheTDMservice.
winlink1000IduTdmMasterClockAct
ual
1.3.6.1.4.1.4458.1000.2.6.2.
3
Integer RO ActualTrunkusedforTDMMasterClock.
winlink1000IduTdmConfigTable N/A IDUTDMLinksConfigurationtable.
winlink1000IduTdmConfigEntry N/A IDUTDMLinksConfigurationtableentry.
INDEX{winlink1000IduTdmConfigIndex}
winlink1000IduTdmConfigIndex RO Tableindex.
winlink1000IduTdmIfIndex RO Linkindexintheinterfacetable.
winlink1000IduTdmLineCoding 1.3.6.1.4.1.4458.1000.2.6.6.
1.6
Integer RW ThisparameterappliestoT1trunksonly.The
parametercontrolsthelinecoding.Settingthe
valuetoeachoftheindicesappliestoall.A
changeiseffectiveafterthenextopenofthe
TDMservice.
winlink1000IduTdmLoopbackConfig 1.3.6.1.4.1.4458.1000.2.6.6.
1.9
Integer RW Loopbackconfigurationtable.Eachofthe
trunkscanbesetNormalLineloopbackor
Reverselineloopback.Achangeiseffective
immediately.
winlink1000IduTdmLineStatus 1.3.6.1.4.1.4458.1000.2.6.6.
1.10
Integer RO Linestatus.
winlink1000IduTdmCurrentTable N/A IDUTDMLinksStatisticstable.
winlink1000IduTdmCurrentEntry N/A IDUTDMLinksStatisticstableentry.INDEX{
winlink1000IduTdmCurrentIndex}
winlink1000IduTdmCurrentIndex RO Tableindex(Sameas
winlink1000IduTdmLineIndex).
winlink1000IduTdmCurrentBlocks 1.3.6.1.4.1.4458.1000.2.6.7.
1.101
Counter RO Numberofcorrectblockstransmittedtothe
line.
TableD2:PrivateMIBParameters(Sheet22of31)