RADWIN2000UserManual Release2.8.30 D‐27
MIBParameters
winlink1000IduEthernetGbeSuppor
ted
1.3.6.1.4.1.4458.1000.2.3.6 Integer RO SupportedGigabitEthernetinIDU.
winlink1000IduEthernetOduInError
s
1.3.6.1.4.1.4458.1000.2.3.7 Counter RO Thenumberofinboundpack etsthatcontained
errorspreventingthemfrombeingdeliverable
toahigher‐layerprotocol.
winlink1000IduBridgeTpAging 1.3.6.1.4.1.4458.1000.2.4.4.
2
Integer RW Timeoutinsecondsforaging.Notethatforthis
parametertobeeffectivetheODUmustbe
configuredtoHUBmode.Achangeiseffective
immediately.
winlink1000IduTdmTxClockAvailStat
es
1.3.6.1.4.1.4458.1000.2.6.1.
1
Integer RO AvailablestatesoftheTDMTransmitClock
Controleachinputstatusisrepresentedbya
bit.Whenthestateisavailablethebitvalueis
1.Whenthestateisunavailablethebitvalue
is0.Theavailablestatesare:bit2=
Transparentbit3=LocalLoopTimedbit
4=
RemoteLoopTimedbit5=LocalInternalbit6
=RemoteInternal
winlink1000IduTdmT xClockDesiredS
tate
1.3.6.1.4.1.4458.1000.2.6.1.
2
Integer RW RequiredstateoftheTDMTransmitClock
Control.Achangeiseffectiveafterre‐activation
oftheTDMservice.
winlink1000IduTdmTxClockActualSt
ate
1.3.6.1.4.1.4458.1000.2.6.1.
3
Integer RO ActualstateoftheTDMTransmitClockControl.
winlink1000IduTdmMasterClockAva
ilOptions
1.3.6.1.4.1.4458.1000.2.6.2.
1
Integer RO AvailableoptionsoftheTDMMasterClock
Controleachinputstatusisrepresentedbya
bit.Whentheoptionisavailablethebitvalue
is1.Whentheoptionisunavailablethebit
valueis0.Theavailableoptionsare:bit2=
Automaticbit3=Tr unk#1bit4
=Trunk#2bit
5=Trunk#3bit6=Trunk#4Whennooptions
areavailablethereturnedvalueis:1
winlink1000IduTdmMasterClockDes
ired
1.3.6.1.4.1.4458.1000.2.6.2.
2
Integer RW RequiredTDMMasterClock.Achangeis
effectiveafterre‐activationoftheTDMservice.
winlink1000IduTdmMasterClockAct
ual
1.3.6.1.4.1.4458.1000.2.6.2.
3
Integer RO ActualTrunkusedforTDMMasterClock.
winlink1000IduTdmConfigTable N/A IDUTDMLinksConfigurationtable.
winlink1000IduTdmConfigEntry N/A IDUTDMLinksConfigurationtableentry.
INDEX{winlink1000IduTdmConfigIndex}
winlink1000IduTdmConfigIndex RO Tableindex.
winlink1000IduTdmIfIndex RO Linkindexintheinterfacetable.
winlink1000IduTdmLineCoding 1.3.6.1.4.1.4458.1000.2.6.6.
1.6
Integer RW ThisparameterappliestoT1trunksonly.The
parametercontrolsthelinecoding.Settingthe
valuetoeachoftheindicesappliestoall.A
changeiseffectiveafterthenextopenofthe
TDMservice.
winlink1000IduTdmLoopbackConfig 1.3.6.1.4.1.4458.1000.2.6.6.
1.9
Integer RW Loopbackconfigurationtable.Eachofthe
trunkscanbesetNormalLineloopbackor
Reverselineloopback.Achangeiseffective
immediately.
winlink1000IduTdmLineStatus 1.3.6.1.4.1.4458.1000.2.6.6.
1.10
Integer RO Linestatus.
winlink1000IduTdmCurrentTable N/A IDUTDMLinksStatisticstable.
winlink1000IduTdmCurrentEntry N/A IDUTDMLinksStatisticstableentry.INDEX{
winlink1000IduTdmCurrentIndex}
winlink1000IduTdmCurrentIndex RO Tableindex(Sameas
winlink1000IduTdmLineIndex).
winlink1000IduTdmCurrentBlocks 1.3.6.1.4.1.4458.1000.2.6.7.
1.101
Counter RO Numberofcorrectblockstransmittedtothe
line.
TableD‐2:PrivateMIBParameters(Sheet22of31)
Name OID Type
Access
Description