RADWIN2000UserManual Release2.8.30 D36
MIBTraps
MIBTraps
General
EachODUcanbeconfiguredwithupto10differenttrapdestinations.Whenthelinkis
operational,eachODUsendstrapsoriginating frombothSit eAandSiteB.
ThesourceIPaddressofthetrapisthesendingODU. Thetraporiginatorcanbeidentifiedby
thetrapCommunitystringorbythetrapdescriptiontext.
Eachtrapcontainsatrapdescriptionandadditionalrelevantinformationsuchasalarm
severity,interfaceindex,timestampandadditionalparameters.
winlink1000HsuServiceHsuType RW HSUtype(1=Fixed2=Stationary3=Mobile)
winlink1000HsuServiceHsuLevel RW HSUlevel(1..4)
winlink1000HsuEthernetPoESuppor
ted
RO IndicatedifthisHSUhasspecialportforPoE
devices.
winlink1000HsuEthernetPoETempe
rature
RO Holdsthetemperature(Celsius)ofthePOE
component.
winlink1000HsuEthernetPoEEquCo
nsumption
RO Holdstheconsumptionoftheconnected
equipment(milliampere).
winlink1000HsuEthernetPoEEquVol
tage
RO Holdsthevoltageoftheconnectedequipment
(Volt).
winlink1000GeneralTrapDescription 1.3.6.1.4.1.4458.1000.100.1 DisplayString RO Trap'sDescription.UsedforTrapparameters.
winlink1000GeneralTrapSeverity 1.3.6.1.4.1.4458.1000.100.2 Integer RO Trap'sSeverity.UsedforTrapparameters.
winlink1000GeneralCookie 1.3.6.1.4.1.4458.1000.100.3 DisplayString RW ReservedfortheManagerapplicationprovided
withtheproductusedforsavinguser
preferencesaffectingODUoperation.
winlink1000GeneralEcChangesCoun
ter
1.3.6.1.4.1.4458.1000.100.4 Integer RO Thiscounterisinitializedto0afteradevice
resetandisincrementeduponeachelement
constantwriteoperationviaSNMPorTelnet.
winlink1000GeneralTelnetSupport 1.3.6.1.4.1.4458.1000.100.5 Integer RW Enable/DisableTelnetprotocol.
winlink1000GeneralWISupport 1.3.6.1.4.1.4458.1000.100.6 Integer RW Enable/DisableWebInterfaceprotocol.
MandatoryDisabled‐Nooptiontoenablethe
feature.MandatoryEnabled‐Nooptionto
disablethefeature.
TableD2:PrivateMIBParameters(Sheet31of31)