Remote Commands
R&S
®
FSW
1151User Manual 1173.9411.02 ─ 43
● Marker Search (Spectrograms)...........................................................................1170
● Fixed Reference Marker Settings........................................................................1179
● Marker Peak Lists................................................................................................1181
● Noise Measurement Marker................................................................................1184
● Phase Noise Measurement Marker.....................................................................1186
● Band Power Marker.............................................................................................1188
● n dB Down Marker...............................................................................................1192
● Signal Count Marker............................................................................................1195
● Marker Demodulation..........................................................................................1197
● Programming Examples for Using Markers and Marker Functions.....................1200
14.8.3.1 Setting Up Individual Markers
The following commands define the position of markers in the diagram.
CALCulate<n>:DELTamarker<m>:AOFF.........................................................................1151
CALCulate<n>:DELTamarker<m>:LINK.......................................................................... 1151
CALCulate<n>:DELTamarker<ms>:LINK:TO:MARKer<md>..............................................1152
CALCulate<n>:DELTamarker<m>:MODE........................................................................1152
CALCulate<n>:DELTamarker<m>:MREFerence.............................................................. 1153
CALCulate<n>:DELTamarker<m>[:STATe]...................................................................... 1153
CALCulate<n>:DELTamarker<m>:TRACe.......................................................................1154
CALCulate<n>:DELTamarker<m>:X............................................................................... 1154
CALCulate<n>:MARKer<m>:AOFF................................................................................ 1155
CALCulate<n>:MARKer<ms>:LINK:TO:MARKer<md>..................................................... 1155
CALCulate<n>:MARKer<m>[:STATe]..............................................................................1155
CALCulate<n>:MARKer<m>:TRACe.............................................................................. 1156
CALCulate<n>:MARKer<m>:X.......................................................................................1156
CALCulate<n>:DELTamarker<m>:AOFF
This command turns off all delta markers.
Suffix:
<n>
.
Window
<m> irrelevant
Example:
CALC:DELT:AOFF
Turns off all delta markers.
CALCulate<n>:DELTamarker<m>:LINK <State>
This command links delta marker <m> to marker 1.
If you change the horizontal position (x-value) of marker 1, delta marker <m> changes
its horizontal position to the same value.
Tip: to link any marker to a different marker than marker 1, use the CALCulate<n>:
DELTamarker<ms>:LINK:TO:MARKer<md> or CALCulate<n>:MARKer<ms>:
LINK:TO:MARKer<md> commands.
Analyzing Measurements (Basics)