SERVICE PROGRAM MODE TABLES 15 February 2006
5-78
5513 Parts Alarm Level Count Japan Only
1 Normal
Sets the parts replacement alarm counter to sound for the number of copies.
[1~9999 / 350 / 1]
2 DF
Sets the parts replacement alarm counter to sound for the number of scanned
originals.
[1~9999 / 350 / 1]
5514 Parts Alarm Level Japan Only
001 Normal [0~1 / 1 / 1]
002 DF [0~1 / 0 / 1]
5515 SC/Alarm Setting
With NRS (New Remote Service) in use, these SP codes can be set to issue an SC
call when an SC error occurs. If this SP is switched off, the SC call is not issued when
an SC error occurs.
001 SC Call
002 Near End Call
003 End Call
[0~1/1/1]
0: Off
1: On
004 User Call
005 Not Used
006 TX Test
007 Device Information
008 Alarm
009 Illegal Toner
[0~1/1/1]
010 Auto Order Supplies
011 Supply Management Report
[0~1/0/1]
012 Jam/Door Open
[0~1/1/1]