SERVICE PROGRAM MODE TABLES 15 February 2006
5-82
5816 Remote Service
I/F Setting 001
Turns the remote diagnostics off and on.
[0~2/1]
0: Remote diagnostics off.
1: Serial (CSS or NRS) remote diagnostics on.
2: Network remote diagnostics.
CE Call 002
Lets the customer engineer start or end the remote machine check with CSS or
NRS; to do this, push the center report key
Function Flag 003
Enables and disables remote diagnosis over the NRS network.
[0~1/1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
SSL Disable 007
Controls if RCG (Remote Communication Gate) confirmation is done by SSL
during an RCG send for the NRS over a network interface.
[0~1/1]
0: Yes. SSL not used.
1: No. SSL used.
RCG Connect Timeout 008
Sets the length of time (seconds) for the time-out when the RCG (Remote
Communication Gate) connects during a call via the NRS network.
[1~90/1 sec.]
RCG Write to Timeout 009
Sets the length of time (seconds) for the time-out when sent data is written to
the RCG during a call over the NRS network.
[0~100/1 sec.]
RCG Read Timeout 010
Sets the length of time (seconds) for the timeout when sent data is written from
the RCG during a call over the NRS network.
[0~100/1 sec.]
Port 80 Enable 011
Controls if permission is given to get access to the SOAP method over Port 80
on the NRS network.
[0~1/1]
0: No. Access denied
1: Yes. Access granted.
RCG – C Registed 021
This SP displays the Cumin installation end flag.
1: Installation completed
2: Installation not completed
RCG – C Registed Detail 022
This SP displays the Cumin installation status.
0: Basil not registered
1: Basil registered
2: Device registered