[SDPL]
230
[Receive TimeOut]
Set the time period that the product stays in the mode to receive binary data.
When the specified time period has passed, the product's binary reception mode ends, and the SDPL
commands are scanned.
The setting range is from 0 (off) to 9,999 ms.
[Blank Item Feed]
Set whether to feed a label with nothing printed on it when the product receives label formatting
commands that do not generate any printable image.
[Prioritize]
Select the settings to be prioritized for each setting item of the SDPL command. You can set whether
to prioritize settings through the product or through commands.
When you select [Settings] for an item, the setting specified in the [SDPL] menu of the product will be
used.
The setting items are as follows:
[Format Attribute]
Set whether to prioritize the settings through the product or through commands for the format attribute
setting.
The options are as follows:
Commands
Prioritize the settings through commands.
Settings
Prioritize the settings through the product.
[Pause Mode]
Set whether to prioritize the settings through the product or through commands for the pause mode
setting.
The options are as follows:
Commands
Prioritize the settings through commands.
Settings
Prioritize the settings through the product.
[1 Byte Codepage]
Set whether to prioritize the settings through the product or through commands for the 1 byte code
page setting.
The options are as follows: