OnAir 3000 Digital Mixing Console
Operation 5-149
Document generated: 10.10.14
SW V6.0
5.12.4.6 Desk / User GUI / Configuration Tool
Error Code Error Type Error Text / Comment
4100
Warning DESK, No communication with Fader module at Port 43 on Container100.
4101
Warning DESK, File ‚fader3.hex‘ not found. Firmware download to Fader module at Port 43 on Container100 failed.
4102
Warning
DESK, Fader calibration failed, one or more fader uncalibrated on Fader module at Port 43 on Con-
tainer100.
Appears as a result of the fader calibration operation if at least one fader is not within the calibration win-
dow.
4104
Warning DESK, Missing Fader module at Port 12 on Container100.
4105
Warning
DESK, Wrong module type at Port 12 on Container100. A Fader module is expected instead of a Rotary
module.
4106
Warning
DESK, One or more fader uncalibrated on Fader module at Port 43 on Container100.
Appears after startup or after module connection if a fader module reports uncalibrated faders by the well-
ness status message.
4107
Warning
DESK, Could not open port COMX.
Appears during init phase if the specified COM port cannot be opened.
4108
Warning DESK, Main Power Supply fail.
4109
Warning DESK, Redundant Power Supply fail.
4110
Warning DESK, Could not find folder ‘Firmware’.
4111
Info
DESK, Module table was changed. Desk ‘Container100’ must be restarted to take effect of the change.
Appears after Save Config, if First strip number of a module has changed.
4112
Warning
DESK, Could not save file on ‘Container100’: ‘Desk_ModuleTable.xml’.
Appears after Save Config, if file could not be saved.
4113
Warning
DESK, Error in Module table on ‘Container100’. Strips are overlapping or out of configured range. Adjust
‘First strip number’ parameter.
Appears after Save Config, if strips are overlapping or out of configured range.
4114
Warning
DESK, Main meter limit reached. Main meter 1 on OA1K5CentralFader6 module at Port 2 on Container100
not active.
Appears after startup if too many Main Meters are configured in the desk patterns of the configured mod-
ules.
4200
Warning CONFIG, AutoConfig not completed! No input modules detected. No Initial Snapshot created.
4201
Warning CONFIG, AutoConfig not completed! No output modules detected. No Initial Snapshot created.
4202
Warning
CONFIG, AutoConfig cannot complete to map all input signals to LogicalInputs. Increase the number of
LogicalInputs and re-run auto configuration.
4203
Warning
CONFIG, AutoConfig cannot complete to map all output signals to LogicalOutputs. Increase the number of
LogicalOutputs and re-run AutoConfig.
4204
Warning CONFIG, AutoConfig detected unknown IO-Card in Slot 7.
4205
Warning
CONFIG, AutoConfig cannot complete to map all GPInputs to GPInputFunctions. Increase the number of
GPInputFunctions and re-run auto configuration.
4206
Warning
CONFIG, AutoConfig cannot complete to map all GPOutputs to GPOutputFunctions. Increase the number
of GPOutputFunctions and re-run auto configuration.
4211
Warning
CONFIG, Alias is already in use! Alias will not be changed.
The Warning appears if an Alias is defined a second time in the ConfigGUI.
4212
Warning
DESK, The Alias ‘Input 1” appears twice in the range of LogicalInputs of Desk ‘Primary Desk’.
The warning appears during power-up or when the Desk Resource Definition is changed so that two Logi-
cal Inputs in the range of that desk have the same alias, or if such an alias conflict happens during power-
up of a desk container.
Appears only if at least one desk is running, since the DRD is used for the double alias check.
4214
Warning
CONFIG, Not enough DSP channels. The format of input “DVD 5.1” cannot be changed.
Appears when trying to change the format of a logical input from mono or stereo to 5.1 in the Config GUI