OnAir 3000 Digital Mixing Console
Operation 5-171
Document generated: 10.10.14
SW V6.0
Import from a CSV formatted file To import a file click “Tools – Import Labels” and select the file which should
be imported. When importing a file, the labels are assigned according to their
index.
1 RLI 1
E.g. the label of RLogicalInput1 will be set to RLI 1. For OnAir products all
labels will be truncated to 8 characters. Route6000 labels have an unlimited
string length.
If some labels should not be imported, the index of these labels can be deleted
in the CSV file.
Supported Labels These labels may be imported / exported :
Product Inputs Outputs
Assignable
Processes
OnAir3000 /
Route3000
LogicalInputs LogicalOutputs
PatchInputs PatchOutputs
OnAir1500 /
OnAir2500
LogicalInputs LogicalOutputs
Route6000 RLogicalInputs RLogicalOutputs Delays
Downmixes
Dynamics
FadeInOuts
Filters
Generators
Mixers
StereoFormatConverters
Upmixes
SilenceDetections
SilenceDetectionGroups
SilenceSwitchers
SilenceSwitcherGroups
OverloadDetections
OverloadDetectionGroups
5.13.5.3 Import routable sources
Only sources listed in the “routable sources” selection are available to be
patched via Pro-Bel. If e.g. a CONNECT command for SRC 2 arrives, SRC
2 must be a member of the routable sources, otherwise the CONNECT mes-
sage is ignored and the trace window will indicate “invalid source”.
The same CSV formatted file, which is being generated for the label export
(see 5.13.5.2 Import / Export Labels) can be used to define the routable
sources selection. This file can be edited with an editor of choice (e.g. Excel).
Delete all sources that must not be routable sources. For reasons of system
performance it is recommended to limit the number of routable sources to
a minimum. Save the file and re-import it using ‘Tools – Import Routable
Sources’. This process must be performed for every controller session.
5.13.5.4 Bridge Card Firmware
The menu item “Bridge Card Firmware” is only selectable for systems with
SCoreLive. It allows to update the bridge card firmware of an SCoreLive.
5.13.5.5 Backup/Restore

Table of Contents

Other manuals for Studer OnAir 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Studer OnAir 3000 and is the answer not in the manual?

Studer OnAir 3000 Specifications

General IconGeneral
BrandStuder
ModelOnAir 3000
CategoryMusic Mixer
LanguageEnglish

Related product manuals