OnAir 3000 Digital Mixing Console
5-156 Operation
Document generated: 10.10.14
SW V6.0
5.12.4.16 Custom Logics
Error Code Error Type Error Text / Comment
8800
Warning
CUSTOM LOGICS, Connection to CORE ‘System71’ lost. Remote GPIO and Custom Logics from that
CORE are not available.
Appears if the CORE looses the network connection to another CORE of a remote system, from which at
least one logical signal is consumed (Remote GPIO or Custom Logics).
8805
Warning
CUSTOM LOGICS, More than 10 gates cascaded at Gate ‘AND 21’! Source cleared.
Appears during configuration of a source of a Custom Logic, the limit of cascades is exceeded configuring
a new source.
The User Warning appears only on the Configuration Tool, where the source was configured.
8806
Warning
CUSTOM LOGICS, Feedback detected at Gate ‘AND 21’. Source cleared.
Appears during configuration of a source of a Custom Logic, if a feedback results.
The User Warning appears only on the Configuration Tool, where the source was configured.
5.12.4.17 Time Sync Card
Error Code Error Type Error Text / Comment
9000
Warning
TIME SYNC, No communication with Time Sync Card.
Appears during power-up or runtime if the TimeSyncRef is ExtTimeSync and the communication to the
Time Sync Card is lost.
9001
Warning
TIME SYNC, Could not open port COMX.
Appears during init phase if the specified COM port cannot be opened.

Table of Contents

Other manuals for Studer OnAir 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Studer OnAir 3000 and is the answer not in the manual?

Studer OnAir 3000 Specifications

General IconGeneral
BrandStuder
ModelOnAir 3000
CategoryMusic Mixer
LanguageEnglish

Related product manuals