RX2520 M4
Upgrade and Maintenance Manual 397
2 [CSS]
CSS
indicator
off
No critical event detected (CSS
component).
orange on
Prefailure event detected (CSS
component).
For HDDs see also "HDD prefailure
detection" on page 399
orange
flashing
CSS component failure detected.
3
Global Error
indicator,
see also
"iRMC-
related
status
signals" on
page 398
off
No critical event detected (non CSS
component).
orange on
Prefailure event detected (non CSS
component).
orange
flashing
Non CSS component failure detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server
management software
4
HDD/SSD
activity
indicator
green
flashing
Data access in progress.
5
Power-on
indicator
off The server is switched off.
green on
– The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
specified time.
– The server is switched on and
operating normally.
green
flashing
slowly
The BMC firmware is starting up after
the server has been connected to the
mains.
Pos. Label Indicator Status Description