EasyManua.ls Logo

Fujitsu PRIMERGY TX300 S8 - Switching on the Server

Fujitsu PRIMERGY TX300 S8
792 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX300 S8 / RX350 S8 Upgrade and Maintenance Manual 123
Basic hardware procedures
4.14 Switching on the server
V CAUTION!
Before switching on the server, make sure the top / side cover is
closed. In order to comply with applicable EMC regulations
(regulations on electromagnetic compatibility) and satisfy cooling
requirements, the PRIMERGY TX300 S8 / RX350 S8 server must
not run while the top / side cover is removed.
After connecting the server to the mains, it will take about 60 seconds
until the server will switch into standby mode.
Follow the safety instructions in chapter "Important information" on
page 45.
Ê Connect all peripheral cables to the rear connector panel of the server.
Ê Connect and secure the power cords as described in section "Connecting
the server to the mains" on page 118.
Ê Connect all power cords to the power outlets.
I To provide true phase redundancy, the second power supply should
be connected to a different AC power source from the other supply. If
one AC power source should fail, the server will still continue to run.
Figure 72: On / Off button on the front panel
Ê Press the On / Off button to start up the server.
Ê Ensure that the power-on indicator above the On / Off button is lit green.
I For more information, refer to section "Front panel controls and
indicators" on page 786.

Table of Contents

Related product manuals