7.2.6.4 Concluding steps
Ê When working on a tower server, close the HDD bay cover as described in
section "Installing accessible drive and HDD bay covers" on page 105.
Ê Please observe the notes on RAID rebuild in section "Performing a RAID
array rebuild" on page 153.
7.2.7 Removing 2.5-inch HDD / SSD modules
7.2.7.1 Preliminary steps
Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
Customer Replaceable Unit
(CRU)
Average task duration:
5 minutes
Tools: tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0
array if defective.
V CAUTION!
Removing an operational HDD module will
result in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I After replacing the HDD module, RAID rebuild
will be performed as a background process as
described in section "Performing a RAID array
rebuild" on page 153.