TX300 S8 / RX350 S8 Upgrade and Maintenance Manual 283
Hard disk drives / solid state drives
Ê Secure the HDD bay top cover to the chassis with five M3 x 4.5 mm screws
(see blue arrows).
Ê Secure the intrusion switch holder on the HDD bay top cover with one
M3 x 4.5 mm screw (see orange arrow).
7.3.10.7 Cabling the SAS backplanes
Ê Connect SAS and power cables to the 3.5-inch SAS backplanes as
described in section "8x 3.5-inch HDD SAS backplane cabling" on page 245.
7.3.10.8 Concluding steps
Ê "Installing the system fan holder" on page 331
Ê "Installing the system air duct" on page 83
Ê "Closing the server" on page 98
Ê Install HDD modules or HDD dummy modules into the additional HDD slots
as described in sections "Installing a 3.5-inch HDD module" on page 256
and "Installing a 3.5-inch HDD dummy module" on page 261.
I For detailed information on HDD mounting order, refer to section "3.5-
inch HDD configurations" on page 241.
Ê When working on a rack-mounted server:
"Mounting the server in the rack" on page 115
Ê "Connecting the server to the mains" on page 118
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task: "Resuming BitLocker functionality" on page 152

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX300 S8 and is the answer not in the manual?

Fujitsu PRIMERGY TX300 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX300 S8
CategoryServer
LanguageEnglish

Related product manuals