482 Upgrade and Maintenance Manual TX300 S8 / RX350 S8
Main memory
10.4 Replacing memory modules
10.4.1 Preliminary steps
Ê Identify the defective memory slot using the server management software.
Ê "Suspending BitLocker functionality" on page 125.
Ê "Disabling SVOM boot watchdog functionality" on page 127.
Ê "Locating the defective server" on page 57.
Ê "Shutting down the server" on page 62.
Ê "Disconnecting the server from the mains" on page 63.
Ê When working on a rack-mounted server:
"Extending / removing the server from the rack" on page 64
Ê Bring the server to its horizontal position.
Ê Open the side / top cover as described in section "Opening the server" on
page 68.
Ê "Removing the system air duct" on page 81.
Ê Locate the defective memory module using the onboard Local Diagnostic
LEDs as described in section "Onboard indicators and controls" on
page 779.
Upgrade and Repair Unit
(URU)
Average task duration:
10 minutes
Tools: tool-less