EasyManuals Logo

Fujitsu PRIMERGY TX300 S8 User Manual

Fujitsu PRIMERGY TX300 S8
792 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #258 background imageLoading...
Page #258 background image
258 Upgrade and Maintenance Manual TX300 S8 / RX350 S8
Hard disk drives / solid state drives
7.3.7 Removing 3.5-inch HDD modules
7.3.7.1 Preliminary steps
Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V CAUTION!
All data on all HDDs / SSDs in the array will be lost! Be sure to back
up your data before deleting a RAID array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Customer Replaceable Unit
(CRU)
Average task duration:
5minutes
Tools: tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0
array if defective.
V CAUTION!
Removing an operational HDD module will
result in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I After replacing the HDD module, RAID rebuild
will be performed as a background process as
described in section "Performing a RAID array
rebuild" on page 153.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX300 S8 and is the answer not in the manual?

Fujitsu PRIMERGY TX300 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX300 S8
CategoryServer
LanguageEnglish

Related product manuals