430 Upgrade and Maintenance Manual TX300 S8 / RX350 S8
Expansion cards and backup units
Ê After installing or replacing a Modular RAID controller, update the firmware
as described in section "Updating RAID controller firmware" on page 137.
Ê In order to configure an expansion card that has been installed or replaced,
the card’s Option ROM has to be enabled in the system board BIOS. If
applicable, proceed as described in section "Enabling Option ROM scan" on
page 138.
Ê "Enabling SVOM boot watchdog functionality" on page 146
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task: "Resuming BitLocker functionality" on page 152
9.5.3 Removing the SAS RAID controller
9.5.3.1 Preliminary steps
Ê "Suspending BitLocker functionality" on page 125
Ê "Shutting down the server" on page 62
Ê "Disconnecting the server from the mains" on page 63
Ê Remove all external cables from the expansion card to be removed.
Ê When working on a rack-mounted server:
"Extending / removing the server from the rack" on page 64
Ê Bring the server to its horizontal position.
Ê Open the side / top cover as described in section "Opening the server" on
page 68.
Ê "Removing the system air duct" on page 81
Upgrade and Repair Unit
(URU)
Average task duration:
5minutes
Tools: Phillips PH2 / (+) No. 2 screw driver

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX300 S8 and is the answer not in the manual?

Fujitsu PRIMERGY TX300 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX300 S8
CategoryServer
LanguageEnglish

Related product manuals