58 Upgrade and Maintenance Manual TX300 S8 / RX350 S8
Basic hardware procedures
Figure 3: ID indicator on connector panel
When working in a datacenter environment, switch on the ID indicator on the
front and rear connector panels of the server for easy identification.
Ê Press the ID button on the front panel (1) or use the iRMC web frontend or
ServerView Operations Manager user interface to switch on the system ID
indicator LEDs (2).
I For further information, refer to the "ServerView Suite Local Service
Concept (LSC)" manual and "iRMC S4 - Integrated Remote
Management Controller" user guide.
Ê When using ServerView Operations Manager to toggle the ID indicator,
choose Single System View and press the Locate button.
Ê Remember to switch off the ID indicator after the maintenance task has been
concluded successfully.
4.1.2 Determining the error class
The Local Service Concept (LSC) allows you to identify defective server
components. Failure events are assigned to one of two error classes:
– Global Error events that need to be resolved by maintenance personnel
– Customer Self Service (CSS) error events that may be resolved by
operating personnel
Global Error and CSS LEDs indicate, if the defective component is a customer
replaceable unit or if maintenance personnel needs to be dispatched to replace
the part.
I The indicators also light up in standby mode and after a server restart
due to a power failure.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX300 S8 and is the answer not in the manual?

Fujitsu PRIMERGY TX300 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX300 S8
CategoryServer
LanguageEnglish

Related product manuals