Page #567 background imageLoading...
Page #567 background image
TX300 S8 / RX350 S8 Upgrade and Maintenance Manual 567
Accessible drives
Ê Pull the LSD module out of the 3.5-inch installation frame (2).
Ê If the removed LSD module is not to be replaced by a new module, reinstall
the LSD dummy cover.
12.5.2.5 Installing accessible drive dummy covers
I if the 4x 3.5-inch HDD extension box is to be reinstalled in the system,
the following description does not apply. Please proceed as described in
section "Installing the 4x 3.5-inch HDD extension box" on page 296.
Installing accessible drive filler covers
Ê Install an accessible drive filler cover (C26361-K644-C933) into the empty
installation bay 1 as described in section "Accessible drive filler covers" on
page 94.
V CAUTION!
Always replace filler covers into unused drive bays to comply with
applicable EMC regulations and satisfy cooling requirements.
Installing accessible drive covers
Ê Install an accessible drive cover (C26361-K644-C60) into installation bay 1
of the front cover as described in section "Accessible drive covers" on
page 96.
12.5.2.6 Concluding steps
Ê "Installing the system fan holder" on page 331
Ê "Installing the system air duct" on page 83
Ê "Closing the server" on page 98
Ê When working on a rack-mounted server:
"Mounting the server in the rack" on page 115
Ê "Connecting the server to the mains" on page 118

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX300 S8 and is the answer not in the manual?

Fujitsu PRIMERGY TX300 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX300 S8
CategoryServer
LanguageEnglish

Related product manuals