EasyManuals Logo

Fujitsu PRIMERGY TX300 S8 User Manual

Fujitsu PRIMERGY TX300 S8
792 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #791 background imageLoading...
Page #791 background image
TX300 S8 / RX350 S8 Upgrade and Maintenance Manual 791
Appendix
Ê Take the system down to its minimum startup configuration.
Ê Reconnect the AC power cords to the power supply units and secure them
with PSU cable brackets as described in section "Connecting the server to
the mains" on page 118.
Ê Connect a keyboard, mouse and display to the server.
Ê Switch on the server as described in section "Switching on the server" on
page 123.
V CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
The minimum startup configuration must be used exclusively for
diagnostic purposes by maintenance personnel, never in daily
operation!