EasyManua.ls Logo

Gemalto Cinterion EHS6 - Page 195

Gemalto Cinterion EHS6
513 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cinterion
®
EHS6 AT Command Set
8.14 AT^SNMON
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 195 of 513
Parameter Description
This parameter determines the action to be taken for the monitoring command.
0 Reset values
1Set values
2 Query values
0 Value returned in "INS" and "NBC" scan output. Value has no meaning and can
be ignored.
0
(D)
...6 Define number of neighbor cells to be scanned with "NBC" feature.
Network Color Code
Base Station Color Code
Write Command
Configure neighbor cell scan output (<action>=1).
AT^SNMON="NBC/CFG/3GPP", <action>, <ratNBC>, <cellNo>
Response(s)
^SNMON: "NBC/CFG/3GPP", 2G, <cellNo>
^SNMON: "NBC/CFG/3GPP", 3G, <cellNo>
OK
ERROR
+CME ERROR: <err>
Write Command
Query configuration of neighbor cell scan output (<action>=2), or reset default configuration (<action>= 0).
AT^SNMON="NBC/CFG/3GPP", <action>
Response(s)
If <action>= 2 to query configuration:
^SNMON: "NBC/CFG/3GPP", 2G, <cellNo>
^SNMON: "NBC/CFG/3GPP", 3G, <cellNo>
If <action>= 0 <cellNo> will be reset to 0:
^SNMON: "NBC/CFG/3GPP", 2G, 0
^SNMON: "NBC/CFG/3GPP", 3G, 0
OK
ERROR
+CME ERROR: <err>
PIN Last Reference(s)
- - - 3GPP TS 45.008 [50]
<action>
(num)
<reserved>
(num)
<cellNo>
(num)(NV)
<ncc>
(num)
<bcc>
(num)

Table of Contents