EasyManuals Logo

Gemalto Cinterion EHS6 User Manual

Gemalto Cinterion EHS6
513 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #298 background imageLoading...
Page #298 background image
Cinterion
®
EHS6 AT Command Set
11.8 AT+CGEQMIN
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 298 of 513
This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
[0] no
1yes
2 no detect
This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the
other SAP, in milliseconds.
[0] subscribed value
10...150 (value needs to be divisible by 10 without remainder)
200...950 (value needs to be divisible by 50 without remainder)
1000...4000 (value needs to be divisible by 100 without remainder)
This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS bearer com-
pared to the SDUs of the other bearers.
[0] subscribed
1
2
3
Numeric parameter that specifies characteristics of the source of the submitted SDUs for a PDP context. This
parameter should be provided if the Traffic class is specified as conversational or streaming.
[0] Characteristics of SDUs is unknown
1 Characteristics of SDUs corresponds to a speech source
Numeric parameter that indicates signalling content of submitted SDUs for a PDP context. This parameter
should be provided if the Traffic class is specified as interactive
[0] PDP context is not optimized for signalling
1 PDP context is optimized for signalling
Packet Data Protocol Type
“IP“
Note
If QOS settings are configured with AT+CGQMIN and AT+CGEQMIN in parallel the MT will use only the
AT+CGEQMIN settings for connection setup while the AT+CGQMIN settings are ignored.
<Delivery of erroneous SDUs>
(num)(NV)
<Transfer delay>
(num)(NV)
<Traffic handling priority>
(num)(NV)
<Source Statistics Descriptor>
(num)(NV)
<Signaling Indication>
(num)(NV)
<PDP_type>
(str)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion EHS6 and is the answer not in the manual?

Gemalto Cinterion EHS6 Specifications

General IconGeneral
BrandGemalto
ModelCinterion EHS6
CategoryControl Unit
LanguageEnglish

Related product manuals