Cinterion
®
EHS6 AT Command Set
12.1 SMS Parameters
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 324 of 513
Status
3GPP TS 23.040 [36] TP-Status in integer format
0...255
Message status
3GPP TS 27.005 [44] Interface of SMS and CB. Indicates the status of message in memory.
Type of Destination Address
3GPP TS 24.011 [39] TP-Destination-Address Type-of-Address octet in integer format (when first character of
<da> is + (IRA 43) default is 145, otherwise default is 129)
0...255
Type of Originating Address
3GPP TS 24.011 [39] TP-Originating-Address Type-of-Address octet in integer format (default refer <toda>)
Type of Recipient Address
3GPP TS 24.011 [39] TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda>)
Type of Service Center Address
3GPP TS 24.011 [39] RP SC address Type-of-Address octet in integer format (default refer <toda>)
<st>
(num)
<stat>
(str)
Description text mode (<mode>=1) PDU mode (<mode>=0) Default
Received unread mes-
sages
"REC UNREAD" 0 for SMS reading com-
mands
Received read messages "REC READ" 1
Stored unsent messages "STO UNSENT" 2 for SMS writing com-
mands
Stored sent messages "STO SENT" 3
All messages "ALL" 4
<toda>
(num)
<tooa>
(num)
<tora>
(num)
<tosca>
(num)