Cinterion
®
EHS6 AT Command Set
2.13 AT^SPOW
EHS6_ATC_V03.001 15/12/3
Confidential / Released
Page 81 of 513
0 Value 0 applies only to <mode>=0 or 1. Note that the AT^SPOW? read com-
mand response value of <awake> is always equal 0 when power saving is off.
3...1000
(D)
...65535 In SLEEP mode (<mode>=2), time in milliseconds the ME remains awake after
the last sent character.
Minimum value: 3 ms, recommended 1000 ms. <timeout> values below 3
are denied with ERROR.
<timeout> value cannot be lower than <awake> value. If <timeout> is set
to lower value than <awake> it will be automatically set to be equal <awake>.
0 Value 0 applies only to <mode>=0 or 1. Note that the AT^SPOW? read com-
mand response value of <awake> is always equal 0 when power saving is off.
3
(D)
...255 In SLEEP mode (<mode>=2), active period of CTS0/CTS1 in milliseconds
when ME is listening to paging messages from the base station and the AT
command interface is enabled.
Minimum and recommended value: 3 ms. Lower <awake> values are denied
with ERROR. Setting a higher value is recommended only when the TE flow
control is too slow.
<timeout>
(num)(NV)
<awake>
(num)(NV)