5. If the issue persists, replace the fuser.
6. If error still remains, replace the Fuser Power Supply assembly Part number: RM2-7125-000CN.
50.2X.YZ
Description
Fuser warm-up error
Recommended action
1. Remove and reinstall the fuser. Make sure that it is seated correctly.
2. Make sure that there is no residual paper in the fuser.
3. Check the printer power source. Make sure that the power source meets printer requirements. Make sure
that the printer is the only device using the circuit.
4. Check the connector (J50) between the fuser and printer. If the connector is damaged, replace the
connector assembly or the Fuser
5. Reconnect the connector (J128) on the DC controller PCA, connector (J600) on the low voltage power
supply assembly and the connectors (J6002 and J6003) on the fuser power supply assembly
6. If the issue persists, replace the fuser.
7. If error still remains, replace the fuser power supply assembly.
Fuser Power Supply assembly Part number: RM2-7125-000CN
8. Replace the low-voltage power assembly.
50.3X.YZ
Description
High fuser temperature
Recommended action
1. Remove and reinstall the fuser. Make sure that it is seated correctly.
2. Make sure that there is no residual paper in the fuser.
3. Check the paper type setting in the printer control panel menus and in the print driver. Make sure that
the settings match and are correct for the type of media being used.
4. Check the connector (J50) between the fuser and printer. If the connector is damaged, replace the
connector assembly or the Fuser.
5. If the issue persists, replace the fuser.
6. If error still remains, replace the Fuser Power Supply assembly Part number: RM2-7125-000CN.
50.4X.YZ
Description
Drive circuit fault
ENWW Tools for troubleshooting 333