59.00.30 or 59.00.40: Fuser error
Description
Fuser motor (M4) start up error or fuser motor (M4) rotational error.
Recommended action
1. Turn the printer o, then back on.
2. Open right door and remove fuser. Rotate fuser gears to ensure they move freely, if they do not replace
the fuser.
3. Run the fuser motor drive test in the actuator drive mode to verify that the fuser motor is functioning
properly. If it is not, replace the fuser motor. PN: RM2-0077-000CN
4. Reconnect the connector (J44) of the fuser motor and connector (J114) on the DC controller PCA.
59.00.B0 Replace Toner Collection Unit
Description
The toner collection unit (TCU) is full.
Recommended action
1. Check the toner collection unit. If the unit is full, replace it.
2. Toner can clog the ITB if the toner collection unit is full.
59.00.C0
Description
Developer alienation motor (M6) error
Recommended action
1. Turn the printer o, then back on.
2. Run the sensor test in the sensor monitor mode to verify that the developer home position sensor is
functioning properly. If it is not, replace the main drive assembly.
3. Run the developer alienation drive test in the actuator drive mode to verify that the developer alienation
drive is functioning properly. If it is not, replace the developer alienation motor. PN: RK2-6027-000CN
stepping motor
4. If the printer has been serviced, check the connector (J46) on the developer disengagement motor and
the connector (J132) on the DC controller PCA.
59.00.F0
Description
T1 alienation mechanism failure.
Recommended action
1. Turn the printer o, then back on.
2. Make sure that the ITB is correctly installed.
346 Chapter 2 Solve problems ENWW