EasyManua.ls Logo

Juniper JUNOS - NETWORK OPERATION GUIDE REV1 - Page 103

Juniper JUNOS - NETWORK OPERATION GUIDE REV1
722 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Using the Basic Monitoring Method ! 67
Chapter 11: Understanding the Method and Tools for Monitoring Router Components
Temperature The chassis temperature
exceeded 55 degrees, the fans
turned on to full speed, and one
or more fans have failed
! Check the room
temperature.
! Check the air filter and
replace it.
! Check the air flow.
! Check the fan.
Yellow
The chassis temperature
exceeded 65 degrees C and the
fans turned on to full speed.
! Check the room
temperature.
! Check the air filter and
replace it.
! Check the air flow.
! Check the fan.
Yellow
The chassis temperature
exceeded 65 degrees C and a
fan failed. If this condition
persists for more than 4
minutes, the router shuts down.
! Check the room
temperature.
! Check the air filter and
replace it.
! Check the air flow.
! Check the fan.
Red
The chassis temperature
exceeded 75 degrees C. If this
condition persists for more than
4 minutes, the router shuts
down.
! Check the room
temperature.
! Check the air filter and
replace it.
! Check the air flow.
! Check the fan.
Red
The temperature sensor failed. For technical support, open
a support case using the
Case Manager link at
http://www.juniper.net
/support/
or call
1-888-314-JTAC (within the
United States) or
1-408-745-9500 (outside
the United States).
Red
Chassis
Component
Alarm Condition Remedy
Alarm
Severity

Table of Contents