Monitoring the FIC Status ! 445
Chapter 34: Monitoring the FIC
Monitoring the FIC Status
If the FIC fails, no information about chassis components is available through the
JUNOS software command-line interface (CLI).
Steps To Take To monitor the FIC status, follow these steps:
1. Understand FIC Slot Numbering on page 445
2. Display FIC Status at the Command Line on page 445
3. Check FIC LEDs on page 446
Step 1: Understand FIC Slot Numbering
Figure 179 shows the FIC location and numbering in the M7i router. The FIC is
located in FPC 1 slot 3.
Figure 179: FIC Numbering
Step 2: Display FIC Status at the Command Line
Action To display the FIC status, use the following CLI command:
user@host> show chassis pic pic-slot 3 fpc-slot 1
Sample Output
user@host>
show chassis pic pic-slot 3 fpc-slot 1
PIC fpc slot 1 pic slot 3 information:
Type 1x G/E, 1000 BASE
ASIC type QGE FPGA
State Online
PIC version 1.4
Uptime 12 hours, 11 minutes, 39 seconds
PIC Port Information:
Port Cable SFP SFP Vendor
Number Type Vendor Name Part Number
0 UNKNOWN CABLE
What It Means Since the FIC is located in FPC 1 slot 3, you must specify its location with the show
chassis pic
CLI command. The command output displays the FIC information, such
as the FIC type, ASIC type, operating status, PIC version, and the amount of time
the FIC has been online. The command output also displays port cable information.
0/3
1/3 1/2
0/2 0/1 0/0
PICs
FPC1
FPC0
FIC
Built-in tunnel interface
and optional ASM
g003231