JUNOS Internet Software Network Operations Guide: Hardware
628 ! Displaying HCM Alarms
user@host>
request chassis routing-engine master switch
warning: Traffic will be interrupted while the PFE is re-initialized
Toggle mastership between routing engines ? [yes,no] (no) yes
Resolving mastership...
Message from syslogd@host cfeb at Jan 28 15:10:37 ...
argh cfeb RDP: Remote side reset connection:
rdp.(scb:17408).(serverRouter:chassis)
Message from syslogd@host cfeb at Jan 28 15:10:37 ...
argh cfeb RDP: Remote side reset connection: rdp.(scb:17409).(serverRouter:pfe)
Message from syslogd@host cfeb at Jan 28 15:10:37 ...
argh cfeb CM: ALARM SET: (Major) RE chassis socket closed abruptly
Complete. The local routing engine becomes the master.
Displaying HCM Alarms
If a single HCM installed in a routing platform fails, no alarm can be sent. However,
if it is a dual system, the following alarm is displayed when the backup Routing
Engine takes over.
Action To view an HCM alarm when the backup Routing Engine takes over, use the
following CLI command:
user@host> show chassis alarms
Sample Output
user@host>
show chassis alarms
1 alarm currently active
Alarm time Class Description
2005-02-16 22:10:27 UTC Minor Backup RE Active
Verifying HCM Failure
Action To view current HCM status when the backup Routing Engine takes over, use the
following CLI command.
user@host> show chassis routing-engine
Sample Output
user@host>
show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Backup
Election priority Master (default)
Temperature 33 degrees C / 91 degrees F
DRAM 2048 MB
Memory utilization 13 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percent
Model RE-3.0
Serial ID P10865703096
Start time 2005-02-16 22:13:19 UTC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper JUNOS - NETWORK OPERATION GUIDE REV1 and is the answer not in the manual?

Juniper JUNOS - NETWORK OPERATION GUIDE REV1 Specifications

General IconGeneral
BrandJuniper
ModelJUNOS - NETWORK OPERATION GUIDE REV1
CategorySoftware
LanguageEnglish

Related product manuals