JUNOS Internet Software Network Operations Guide: Hardware
170 ! Checking for FPC Alarms
For more information about the craft interface, see “Monitoring the Craft Interface”
on page 197 or the appropriate hardware guide.
For more information about craft interface alarms, see “Display the Current Router
Alarms” on page 61.
Step 2: Display FPC Error Messages in the System Log File
Action To check for FPC error messages in the system log messages file, use the following
CLI command:
user@host> show log messages | match fpc
Check for error messages at least 5 minutes before and after an FPC alarm occurs.
Sample Output The following output displays when you browse through the messages log file using
the time and date stamp to look for error messages that occur 5 minutes before and
after the FPC event:
user@host>
show log messages
Mar 10 09:20:31 cls-edge-02 ssb RDP: Keepalive timeout for
rdp.(scb:chassis).(fpc1:36865) (elapsed 5595)
Mar 10 09:20:33 cls-edge-02 ssb SSB(0): Slot 0, serial number S/N BD9709.
Mar 10 09:20:37 cls-edge-02 ssb BCHIP 1: SRAM test failed.
Mar 10 09:20:37 cls-edge-02 ssb CM(0): Slot 1: B-chip diagnostics failed
Mar 10 09:20:37 cls-edge-02 ssb CM(0): Slot 1: Unrecoverable error; probe failed
Mar 10 09:20:37 cls-edge-02 ssb CM(0): Slot 1: Too many unrecoverable errors,
going off-line
Mar 10 09:20:37 cls-edge-02 ssb CM(0): ALARM SET: (Major) Slot 1: Too many
unrecoverable errors
Mar 10 09:20:37 cls-edge-02 ssb CM(0): Slot 1: Off-line
Mar 10 09:20:38 cls-edge-02 ssb PFEMAN: FPC socket closure indicated
Mar 10 09:20:38 cls-edge-02 ssb PFEMAN: closing FPC 1 socket
Mar 10 09:20:42 cls-edge-02 ssb PFEMAN: FPC socket closure indicated
Mar 10 09:20:42 cls-edge-02 ssb PFEMAN: close on unlisted socket, 0xb0e200
The following output displays when you use the | match filter command to look for
specific information in the
messages log file:
user@host>
show log messages | match fpc
Mar 31 05:07:58 bopper fpc6 D4-6/0 AMCC: Transmitter laser bias out of range.
Mar 31 05:08:37 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 2, power on
timeout, retry 1, restarting
Mar 31 05:08:44 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 5, power on
timeout, retry 1, restarting
Mar 31 05:10:19 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 2, power on
timeout, retry 2, restarting
Mar 31 05:10:26 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 5, power on
timeout, retry 2, restarting
Mar 31 05:12:00 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 2, power on
timeout, retry 3, restarting
Mar 31 05:12:07 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 5, power on
timeout, retry 3, restarting
Mar 31 05:13:41 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: FPC 2
unresponsive, setting offline!
Mar 31 05:13:48 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: FPC 5
unresponsive, setting offline!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper JUNOS - NETWORK OPERATION GUIDE REV1 and is the answer not in the manual?

Juniper JUNOS - NETWORK OPERATION GUIDE REV1 Specifications

General IconGeneral
BrandJuniper
ModelJUNOS - NETWORK OPERATION GUIDE REV1
CategorySoftware
LanguageEnglish

Related product manuals