Getting SCG Hardware Information ! 323
Chapter 23: Monitoring the SCGs
9. Bring the SCG online by doing one of the following:
! Use the following CLI command:
user@host> request chassis scg online slot number
! Press the online/offline button until the green ONLINE LED lights.
10. Verify that the SCG is online by using the following CLI command:
user@host> request chassis scg online slot number
If the replaced SCG is online, the removed SCG has failed. Return the SCG as
described in “Return the Failed Component” on page 86.
Getting SCG Hardware Information
Steps To Take To get the SCG hardware information, follow these steps:
1. Display the SCG Hardware Information on page 323
2. Locate the SCG Serial Number ID Label on page 324
Step 1: Display the SCG Hardware Information
Action To display the SCG hardware information, use the following CLI command:
user@host> show chassis hardware
Sample Output
user@host>
show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis abcdef T320
Midplane REV 01 710-004339 AY4529
FPM GBUS REV 02 710-004461 AY4511
FPM Display REV 02 710-002897 HF6094
CIP REV 05 710-002895 HC0468
PEM 1 Rev 01 740-004359 2708013 Power Entry Module
SCG 0 REV 06 710-004455 AY4526
SCG 1 REV 06 710-004455 AY4523
What It Means The command output displays the SCG slot number, revision level, part number,
and serial number.