Displaying Redundant PCG Hardware Information ! 597
Chapter 45: Monitoring Redundant PCGs
Displaying Redundant PCG Hardware Information
Action To display redundant PCG hardware information, use the following JUNOS software
command-line interface (CLI) command:
user@host> show chassis hardware
Sample Output
user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis 20079 M160
Midplane REV 03 710-001245 AB4132
FPM CMB REV 02 710-001642 AB3264
FPM Display REV 02 710-001647 AB3046
CIP REV 04 710-001593 AB3284
PEM 0 Rev 03 740-001243 KM28409 DC
PEM 1 Rev 03 740-001243 KM13359 DC
PCG 0 REV 02 710-001568 AB3013
PCG 1 REV 02 710-001568 AB3000
[...Output truncated...]
What It Means The command output displays the PCG slot number, revision level, part number,
and serial number.
Monitoring Redundant PCG Status
Steps To Take To monitor the PCG status, follow these steps:
1. Monitor the Redundant PCG Environmental Status on page 597
2. Display the Redundant PCG Status from the Craft Interface on page 598
3. Check the PCG LED Status on the Faceplate on page 599
Step 1: Monitor the Redundant PCG Environmental Status
Action To monitor the PCG environment status, use the following CLI command:
user@host> show chassis environment
Sample Output
user@host> show chassis environment
Class Item Status Measurement
Power PEM 0 OK
PEM 1 OK
Temp PCG 0 OK 41 degrees C / 105 degrees F
PCG 1 OK 39 degrees C / 102 degrees F
[...Output truncated...]
What It Means The command output displays the slot number, status, and temperature of each
PCG.