JUNOS Internet Software Network Operations Guide: Hardware
564 ! Displaying Redundant Control Board Mastership
Step 1: Check the Redundant Control Board Environmental Status
Action To check the redundant Control Board environmental status, use the following CLI
command:
user@host> show chassis environment cb
Sample Output
t640@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 29 degrees C / 84 degrees F
Power:
1.8 V 1805 mV
2.5 V 2501 mV
3.3 V 3293 mV
4.6 V 4725 mV
5.0 V 5032 mV
12.0 V 11975 mV
3.3 V bias 3286 mV
8.0 V bias 7589 mV
GBUS Revision 40
FPGA Revision 7
CB 1 status:
State Online Standby
Temperature 32 degrees C / 89 degrees F
Power:
1.8 V 1802 mV
2.5 V 2482 mV
3.3 V 3289 mV
4.6 V 4720 mV
5.0 V 5001 mV
12.0 V 11946 mV
3.3 V bias 3274 mV
8.0 V bias 7562 mV
GBUS Revision 40
FPGA Revision 7
What It Means The command output displays which Control Board is master and standby.
Additionally, the command output displays the Control Board state, redundancy
status, temperature, power source, and circuitry revision level for each Control
Board installed in the router chassis.
CB1 is shown in standby mode, and is the
redundant Control Board.
Alternative Action To display the environmental status of a particular Control Board, use the following
JUNOS CLI operational mode command:
t640@host> show chassis environment cb slot