JUNOS Internet Software Network Operations Guide: Hardware
70 ! Using the Basic Monitoring Method
Temperature The chassis temperature
exceeded 55 degrees C, the
fans turned on to full speed,
and one or more fans failed.
! Check the room
temperature.
! Check the air filter and
replace it.
! Check the air flow.
! Check the fan.
Yellow
The chassis temperature
exceeded 65 degrees, and
the fans turned on to full
speed.
! Check the room
temperature.
! Check the air filter and
replace it.
! Check the air flow.
! Check the fan.
Yellow
The chassis temperature
exceeded 65 degrees C and a
fan failed. If this condition
persists for more than 4
minutes, the router shuts
down.
! Check the room
temperature.
! Check the air filter and
replace it.
! Check the air flow.
! Check the fan.
Red
The chassis temperature
exceeded 75 degrees C. If
this condition persists for
more than 4 minutes, the
router shuts down.
! Check the room
temperature.
! Check the air filter and
replace it.
! Check the air flow.
! Check the fan.
Red
The temperature sensor
failed.
For technical support, open
a support case using the
Case Manager link at
http://www.juniper.net
/support/
or call
1-888-314-JTAC (within the
United States) or
1-408-745-9500 (outside
the United States).
Red
Chassis
Component
Alarm Condition Remedy
Alarm
Severity

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper JUNOS - NETWORK OPERATION GUIDE REV1 and is the answer not in the manual?

Juniper JUNOS - NETWORK OPERATION GUIDE REV1 Specifications

General IconGeneral
BrandJuniper
ModelJUNOS - NETWORK OPERATION GUIDE REV1
CategorySoftware
LanguageEnglish

Related product manuals