Configuration
7-357
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C1091 CODE 141 2 {1} 2000 FEVAN1
Selection of the target code
C1092 SUBCODE 0 0 {1} 255 FEVAN1
Selection of the target subcode
C1093 NUMERATOR 1.0000 0.0001 {0.0001} 100000.0000 FEVAN1
Numerator
C1094 DENOMINATOR 0.0001 0.0001 {0.0001} 100000.0000 FEVAN1
Denominator
C1095 OFFSET 0 0 {1} 1000000000 FEVAN1
Offset setting
[C1096] IN 1000 FIXED0% → Selection list 1 FEVAN1
Configuration - analog input signal
[C1097] → Selection list 2
FEVAN 1
1 LOAD 1000 FIXED0
Configuration - digital input signals
2 BUSY-IN 1000 FIXED0
3 FAIL-IN 1000 FIXED0
C1098 (C1096)
0
-32768 {1} 32767
C1099
0
1 (C1097/1)
2 (C1097/2)
3 (C1097/3)
C1100 FUNCTION 1 1
2
Return
Hold
FCNT1
Function selection
[C1101] → Selection list 1
FCNT1
1 LD-VAL 1000 FIXED0%
Configuration - analog input signals
2 CMP-VAL 1000 FIXED0%
[C1102] → Selection list 2
FCNT1
1 CLKUP 1000 FIXED0
Configuration - digital input signals
2 CLKDWN 1000 FIXED0
3 LOAD 1000 FIXED0
C1103
0
-32768 {1} 32768
1 (C1101/1)
2 (C1101/2)
C1104
0
1 (C1102/1)
2 (C1102/2)
3 (C1102/3)
C1105 FUNCTION 1 1
2
Return
Hold
FCNT2
Function selection
[C1106] → Selection list 1
FCNT2
1 LD-VAL 1000 FIXED0%
Configuration - analog input signals
2 CMP-VAL 1000 FIXED0%
[C1107] → Selection list 2
FCNT2
1 CLKUP 1000 FIXED0
Configuration - digital input signals
2 CLKDWN 1000 FIXED0
3 LOAD 1000 FIXED0
C1108
0
-32768 {1} 32768
1 (C1106/1)
2 (C1106/2)
C1109
0
1 (C1107/1)
2 (C1107/2)
3 (C1107/3)
C1110 FUNCTION 1 1
2
Return
Hold
FCNT3
Function selection