4
FUNCTIONS
4.1 Function List
4 - 2
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
FUNCTIONS
5
ACCESS VIA NETWORK
MODULES
6
PREPARATORY
PROCEDURES AND
SETTING
7
I/O NUMBER
ASSIGNMENT
8
MEMORIES AND FILES
: Available, : Available but partially restricted, : N/A
(To the next page)
Table 4.1 List of C Controller module functions (continued)
Function Description
Availability
Reference
section
Q12DC
CPU-V
Q06C
CPU-V
Q06C
CPU-V-B
Error time output mode
setting
Set whether to clear or hold the outputs to output modules, I/
O combined modules, and intelligent function modules when
a stop error occurs in the C Controller module.
Page 4-36,
Section 4.9
Hardware error time CPU
operating mode setting
Set whether to stop or run the C Controller module when a
hardware error occurs in an intelligent function module.
Page 4-37,
Section 4.10
Intelligent function module
and interrupt module
switch setting
Configure the settings for intelligent function modules and
interrupt modules. (For details, refer to the manual for each
module.)
Page 4-38,
Section 4.11
Watchdog timer (WDT)
Detects a hardware error or a user program error of the C
Controller module.
Page 4-40,
Section 4.12
Interrupt from intelligent
function module
Issues an interrupt event (I50 to I255) in response to an
interrupt request from an intelligent function module.
Page 4-42,
Section 4.13
Connection between C
Controller module and
GOT (microcomputer
connection)
Accesses a GOT through the RS-232 interface of the C
Controller module.
Page 4-47,
Section 4.14
Telnet function
From the Telnet tool of the development environment
(personal computer), allows simple remote debugging (task
information display, memory dumping, etc.) of the C
Controller.
Without using Workbench or Tornado, simple remote
debugging is available.
Page 4-48,
Section 4.15
Communication function
with peripheral devices
through an Ethernet port
Connects a peripheral device (such as GX Developer) to the
Ethernet port on the C Controller module with an Ethernet
cable to perform communications.
Page 4-53,
Section 4.16
Unmounting
CompactFlash card
CompactFlash card can be unmounted with the RESET/
SELECT switch on the C Controller module.
Page 6-24,
Section 6.4,
Page 6-67,
Section
6.8.3
Login user access
restriction
Restricts parameter writing from FTP or each utility and use
of the Telnet function, by setting (adding/deleting) login users
for the C Controller module.
Page 6-88,
Section 6.11