A - 12
OPERATING PRECAUTIONS
This section provides the following precautions.
(1) Precautions for system configurations
(a) Supported modules
In a system configuration where a C Controller module is used, some main and
extension base units cannot be used ( Page 2-16, Section 2.1.6), and also
use of some modules is restricted by their function versions ( Page 2-17,
Section 2.2).
(b) Multiple CPU system
1) Applicable CPU modules
For the CPU modules that can be used with a C Controller module in a multiple
CPU system, refer to the following.
Page 11-11, Section 11.2.1
2) MT Developer connection (Version 00Y or earlier) in a multiple CPU system
When a multiple CPU system includes a C Controller module set as CPU No.1
and a Motion CPU, a communication test of MT Developer (Version 00Y or
earlier) cannot be performed. (The Motion CPU communication test error
(error code: 12288) will occur.)
To perform the communication test from MT Developer, use either of the
following methods.
Use MT Developer Version 00Z or later.
When using MT Developer Version 00Y or earlier, modify the multiple
CPU system configuration so that CPU No.1 is a programmable controller
CPU.
(c) Time adjustment and time notification of GOT
In a multiple CPU system configuration, when time adjustment or time notification
is performed in a GOT connected to C Controller modules for CPU No. 2 to No. 4,
it is executed to CPU No. 1.
In this case, to match the clock data between the C Controller modules assigned
to CPU No. 2 to No. 4 and the GOT, use the multiple CPU clock synchronization
function.
Page 4-33, Section 4.7.1
(d) Connection with GX Works2/GX Developer
For the connection with GX Works2/GX Developer, refer to the following.
Page 2-29, Section 2.4 (7)
Precautions for Refer to
System configurations
Page A-12
Standard RAM, standard ROM, and CompactFlash card
Page A-13
Battery
Page A-15
Clock setting
Page A-16
Starting the C Controller module
Page A-16
Network configurations
Page A-17
Relation between system tasks and the system watchdog timer, user
watchdog timer, and link device refresh cycles
Page A-17
For the Wind River Systems product
Page A-17